Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Server into a Telco Rack
Installing the Server into a Telco Rack
To install the SuperServer 6015B-3/6015B-T into a Telco type rack, use two L-
shaped brackets on either side of the chassis (four total). First, determine how far
follow the server will extend out the front of the rack. Larger chassis should be
positioned to balance the weight between front and back. If a bezel is included on
your server, remove it. Then attach the two front brackets to each side of the chas-
sis, then the two rear brackets positioned with just enough space to accommodate
the width of the rack. Finish by sliding the chassis into the rack and tightening the
brackets to the rack.